Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
PLoS One ; 17(9): e0274222, 2022.
Article in English | MEDLINE | ID: covidwho-2021957

ABSTRACT

INTRODUCTION: Using respiratory virus rapid diagnostic tests in the emergency department could allow better and faster clinical management. Point-of-care PCR instruments now provide results in less than 30 minutes. The objective of this study was to assess the impact of the use of a rapid molecular diagnostic test, the cobas® Influenza A/B & RSV Assay, during the clinical management of emergency department patients. METHODS: Patients (adults and children) requiring admission or suffering from an underlying condition at risk of respiratory complications were prospectively recruited in the emergency department of four hospitals in the Brussels region. Physicians' intentions regarding admission, isolation, antibiotic, and antiviral use were collected before and after performing the rapid molecular test. Additionally, a comparison of the analytical performance of this test against antigen rapid tests and viral culture was performed as well as a time-to-result evaluation. RESULTS: Among the 293 patients recruited, 90 had a positive PCR, whereas 44 had a positive antigen test. PCR yielded a sensitivity of 100% for all targets. Antigen tests yielded sensitivities ranging from 66.7% for influenza B to 83.3% for respiratory syncytial virus (RSV). The use of PCR allowed a decrease in the overall need for isolation and treatment by limiting the isolation of negative patients and antibiotic use for positive patients. Meanwhile, antiviral treatments better targeted patients with a positive influenza PCR. CONCLUSION: The use of a rapid influenza and RSV molecular test improves the clinical management of patients admitted to the emergency department by providing a fast and reliable result. Their additional cost compared to antigen tests should be balanced with the benefit of their analytical performance, leading to efficient reductions in the need for isolation and antibiotic use.


Subject(s)
Herpesvirus 1, Cercopithecine , Influenza A virus , Influenza, Human , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Adult , Anti-Bacterial Agents/therapeutic use , Antiviral Agents , Child , Emergency Service, Hospital , Humans , Influenza A virus/genetics , Influenza B virus/genetics , Influenza, Human/diagnosis , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus, Human/genetics , Sensitivity and Specificity
2.
Diagnostics (Basel) ; 12(2)2022 Feb 09.
Article in English | MEDLINE | ID: covidwho-1674536

ABSTRACT

The Lumipulse® G SARS-CoV-2 Ag assay performance was evaluated on prospectively collected saliva and nasopharyngeal swabs (NPS) of recently ill in- and outpatients and according to the estimated viral load. Performances were calculated using RT-PCR positive NPS from patients with symptoms ≤ 7 days and RT-PCR negative NPS as gold standard. In addition, non-selected positive NPS were analyzed to assess the performances on various viral loads. This assay yielded a sensitivity of 93.1% on NPS and 71.4% on saliva for recently ill patients. For NPS with a viral load > 103 RNA copies/mL, sensitivity was 96.4%. A model established on our daily routine showed fluctuations of the performances depending on the epidemic trends but an overall good negative predictive value. Lumipulse® G SARS-CoV-2 assay yielded good performance for an automated antigen detection assay on NPS. Using it for the detection of recently ill patients or to screen high-risk patients could be an interesting alternative to the more expensive RT-PCR.

3.
Front Med (Lausanne) ; 8: 743988, 2021.
Article in English | MEDLINE | ID: covidwho-1523722

ABSTRACT

Introduction: We assessed the usefulness of SARS-CoV-2 RT-PCR cycle thresholds (Ct) values trends produced by the LHUB-ULB (a consolidated microbiology laboratory located in Brussels, Belgium) for monitoring the epidemic's dynamics at local and national levels and for improving forecasting models. Methods: SARS-CoV-2 RT-PCR Ct values produced from April 1, 2020, to May 15, 2021, were compared with national COVID-19 confirmed cases notifications according to their geographical and time distribution. These Ct values were evaluated against both a phase diagram predicting the number of COVID-19 patients requiring intensive care and an age-structured model estimating COVID-19 prevalence in Belgium. Results: Over 155,811 RT-PCR performed, 12,799 were positive and 7,910 Ct values were available for analysis. The 14-day median Ct values were negatively correlated with the 14-day mean daily positive tests with a lag of 17 days. In addition, the 14-day mean daily positive tests in LHUB-ULB were strongly correlated with the 14-day mean confirmed cases in the Brussels-Capital and in Belgium with coinciding start, peak, and end of the different waves of the epidemic. Ct values decreased concurrently with the forecasted phase-shifts of the diagram. Similarly, the evolution of 14-day median Ct values was negatively correlated with daily estimated prevalence for all age-classes. Conclusion: We provide preliminary evidence that trends of Ct values can help to both follow and predict the epidemic's trajectory at local and national levels, underlining that consolidated microbiology laboratories can act as epidemic sensors as they gather data that are representative of the geographical area they serve.

4.
J Clin Microbiol ; 60(1): e0169821, 2022 01 19.
Article in English | MEDLINE | ID: covidwho-1511413

ABSTRACT

This first pilot trial on external quality assessment (EQA) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) whole-genome sequencing, initiated by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Genomic and Molecular Diagnostics (ESGMD) and the Swiss Society for Microbiology (SSM), aims to build a framework between laboratories in order to improve pathogen surveillance sequencing. Ten samples with various viral loads were sent out to 15 clinical laboratories that had free choice of sequencing methods and bioinformatic analyses. The key aspects on which the individual centers were compared were the identification of (i) single nucleotide polymorphisms (SNPs) and indels, (ii) Pango lineages, and (iii) clusters between samples. The participating laboratories used a wide array of methods and analysis pipelines. Most were able to generate whole genomes for all samples. Genomes were sequenced to various depths (up to a 100-fold difference across centers). There was a very good consensus regarding the majority of reporting criteria, but there were a few discrepancies in lineage and cluster assignments. Additionally, there were inconsistencies in variant calling. The main reasons for discrepancies were missing data, bioinformatic choices, and interpretation of data. The pilot EQA was overall a success. It was able to show the high quality of participating laboratories and provide valuable feedback in cases where problems occurred, thereby improving the sequencing setup of laboratories. A larger follow-up EQA should, however, improve on defining the variables and format of the report. Additionally, contamination and/or minority variants should be a further aspect of assessment.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Laboratories , Laboratories, Clinical , Pilot Projects
5.
J Clin Virol ; 144: 104988, 2021 11.
Article in English | MEDLINE | ID: covidwho-1440171

ABSTRACT

The prediction of SARS-CoV-2 immunity by commercially available serologic tests will be crucial to assess the efficacy of vaccination. We used plaque reduction neutralization testing as the reference standard to evaluate the diagnostic performance of six commercial serologic tests for monitoring SARS-CoV-2 neutralizing antibodies. Euroimmun ELISA anti-spike 1 IgG, Euroimmun anti-spike 1 IgG QuantiVac ELISA, Elecsys Anti-nucleocapsid protein total antibodies, Elecsys Anti-receptor-binding domain total antibodies, VIDAS anti-spike subdomain IgG, and Microblot-Array COVID-19 IgG assay were performed on 228 sera from 89 healthcare workers who participated in a six-month seroprevalence survey. Although all immunoassays demonstrated similar performances, VIDAS SARS-CoV-2 IgG and Euroimmun QuantiVac IgG (area under the curve 0.96 and 0.95 respectively) showed the better ability to detect Nabs. Except for the Elecsys Anti-SARS-CoV-2 and the Elecsys Anti-SARS-CoV-2 S assays, the commercial serologic tests evaluated here showed a significant decrease of antibody titers in the 6-month follow-up samples. Depending on the immunoassay, 21% to 33% of the participants became seronegative, and 16.9% had a loss of neutralizing antibodies. Microblot-Array assay results showed cross-reactivity with HCoVNL63 in only one sample, and this sample showed SARS-CoV-2 neutralizing capacity. In conclusion, our results support the use of VIDAS SARS-CoV-2 IgG, Euroimmun Anti-SARS-CoV-2 ELISA IgG, Euroimmun Anti-SARS-CoV-2 QuantiVac ELISA IgG and Microblot-Array COVID-19 IgG assays to monitor neutralizing antibody response following natural SARS-CoV-2 infection. These immunoassays could facilitate the prediction of post-vaccine protection in the long term and the allocation of booster doses.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , Humans , Sensitivity and Specificity , Seroepidemiologic Studies , Serologic Tests
6.
Front Med (Lausanne) ; 8: 650581, 2021.
Article in English | MEDLINE | ID: covidwho-1200090

ABSTRACT

Introduction: Since the first wave of COVID-19 in Europe, new diagnostic tools using antigen detection and rapid molecular techniques have been developed. Our objective was to elaborate a diagnostic algorithm combining antigen rapid diagnostic tests, automated antigen dosing and rapid molecular tests and to assess its performance under routine conditions. Methods: An analytical performance evaluation of four antigen rapid tests, one automated antigen dosing and one molecular point-of-care test was performed on samples sent to our laboratory for a SARS-CoV-2 reverse transcription PCR. We then established a diagnostic algorithm by approaching median viral loads in target populations and evaluated the limit of detection of each test using the PCR cycle threshold values. A field performance evaluation including a clinical validation and a user-friendliness assessment was then conducted on the antigen rapid tests in point-of-care settings (general practitioners and emergency rooms) for outpatients who were symptomatic for <7 days. Automated antigen dosing was trialed for the screening of asymptomatic inpatients. Results: Our diagnostic algorithm proposed to test recently symptomatic patients using rapid antigen tests, asymptomatic patients using automated tests, and patients requiring immediate admission using molecular point-of-care tests. Accordingly, the conventional reverse transcription PCR was kept as a second line tool. In this setting, antigen rapid tests yielded an overall sensitivity of 83.3% (not significantly different between the four assays) while the use of automated antigen dosing would have spared 93.5% of asymptomatic inpatient screening PCRs. Conclusion: Using tests not considered the "gold standard" for COVID-19 diagnosis on well-defined target populations allowed for the optimization of their intrinsic performances, widening the scale of our testing arsenal while sparing molecular resources for more seriously ill patients.

SELECTION OF CITATIONS
SEARCH DETAIL